배열회수보일러 복수예열기 부식 파손 분석
Hobyung Chae, 김우철, 김희산 et al. · Corrosion Science and Technology · 2021
In this work, we have performed a corrosion failure analysis of a leaking tube connected to an upper header of a condensate pre-heater in a heat recovery steam generator. It was revealed that the leakage position in the tube was the location where the materials were easily vulnerable due to tensile residual stresses induced by the material manufacturing process and welding process. In addition to an imbalance in the module induced by temperature difference during operation of the pre-heater, the weight of the modules and thermal fatigue provoked a type of stress of tensile-tensile fatigue on the tube. Thus, the leakage position of the pre-heater was exposed to the tensile stress on the inner surface of the tube facing the gas, which rendered the unstable oxide layer susceptible to corrosion and the formation of pits on the water side. The cracks propagated along with the degraded microstructure in a transgranular cracking mode under fatigue loading and finally resulted in water leakage.
Cited by 0 works. doi:10.14773/cst.2021.20.2.69
Authors
References
- Stress Behaviors of Superheater Tubes under Load Change Operation in HRSG
- Analysis of a failed pipe elbow in geothermal production facility
- Failure Analysis of a Water Wall Boiler Tube for Power Generation in a District Heating System
- Stress Corrosion Cracking of a Copper Pipe in a Heating Water Supply System
- Evaluation of Stress and Fatigue Life of a Tube Bundle and Header for the High-Pressure Evaporator of a Heat Recovery Steam Generator
- A Study on Welding Distortion and Residual Stress for Tubular Welded Joint
- Fatigue Fracture Analysis of Curved Pipes Under Cyclic Loading
- Static Analysis of Tube to Header Weld Joint Configurations
- 지역난방수 공급관 에어벤트 부식 파손 분석
- Failure Analysis of Air Vent Connected with Heat Supply Pipeline Under Manhole, 맨홀에 설치된 지역난방 열공급관 에어벤트의 전단부 파손 원인 규명