고주파 방사에 의한 루프형 구조물에서의 유도전압 특성
Sang-Won Choi, 권혁면 · 2012
There is a possibility that electrical sparks may occur at discontinuities in metallic structures from distance of close to high power radio/radar transmitters. Voltage may be induced on these metallic structures by the radio-frequency transmitter. In this case, a person who comes into contact with these structure may be undergone a severe electrical shock. In this paper, assessment of the electrical shock and ignition hazards was investigated through experimental which are consisted radio transmitter and metallic loop-type structure in shield room. We measured that the induced voltage was highest at 61 MHz of transmission frequency, and confirmed the possibility of electric shock and explosion induced by a voltage or spark. But it is needed additional research where is opened site.
Cited by 0 works.