고층 건축물 상층부의 동조질량화를 위한 면진시스템의 활용

김태호, 박지형, 김욱종 et al. · 한국지진공학회 춘계학술발표회 논문집 · 2008

The purpose of this study is to examine the possibility of lateral vibration reduction by applying the isolators in the top-story of a tall building. Earthquake and wind loads are applied to the 20, 30 and 50 stories building structures for this purpose. Artificial wind loads are used for the serviceability of the wind vibration. And the responses by these loads are investigated on the structures with 1st mode period that is 0.5, 1.0 and 2.0 times of the 1st mode period of the fixed base structure. Also, the top-story isolation and TMD on the main structure are compared for verifying for the application of isolation system to TMD with top-story mass.