차량소독장치에서 소독약액의 온도제어에 관한 연구
임영일, Dongil Chang, 김정철 et al. · Journal of Agriculture & Life Science · 2015
This study was conducted to improve the conventional vehicle disinfection system that shows very low sterilizing effect at lower temperature than effective temperature of disinfectant solution in winter. Temperature of disinfectant solution sprayed from the nozzles of a improved vehicle disinfection system must be kept within the effective temperature range of 15∼20℃ in winter, and nozzles and hose must not be frozen. In order to achieve two aims mentioned above, we determined proper temperature of disinfectant solution in a tank and thermal capacity of a constant wattage heating cable. Under ambient temperature of –25℃, proper temperature of disinfectant solution in a tank was about 30℃ and proper thermal capacity of a constant wattage heating cable was about 26W m-1.
Cited by 0 works.