페이크패턴에 대한 정립과 화재조사기법연구
신민석, Young Jin Kim, 최원호 et al. · 한국화재감식학회 학회지 · 2017
Among the recent fire cases, fires where the combustion point and the ignition point were different occurred. Generally, fire spots are considered as sources of ignition. However, this kind of fire started to ignite in the lower part, but it left little traces and moved to the upper part, causing a large fire damage. The fire inspector must escape stereotypes. This study is based on the assumption that even if there is no trace of carbonization, it can be a point of ignition. Also, a warehouse with a high gap between the upper and lower layers was made into a rehearsal experiment field. In this study, the fake pattern is established as follows. The fire point is different from the combustion point, leaving no carbonized traces. In addition, we study the technique for accurate fire investigation of these fire patterns
Cited by 0 works.