In nuclear and thermal power plants, turbine output control, a special steam valve that is opened with a hydraulic servo actuator and closed with a large steel spring, is used in high pressure and low pressure steam turbines. This steam control valve should supply an adequate amount of steam during normal power generation operation, but should protect the turbine rotating at high speed (Nuclear power plant 1800 rpm, thermal power plant 3600 rpm) by cutting off the steam supply quickly when an error occurs in the power generation system. This study analyzes the failure of the steam valve in the turbine output control system and the failure of the hydraulic servo actuator that operates the steam valve, and summarizes the results of the improvement.