가축폐수의 호기성 처리를 위한 산소용해기에 관한 연구

손보균, 김신도, Nam Keun Kim et al. · 한국도시환경학회지 · 2007

This studies are to investigate of the oxygen transfer efficiency for oxygen dissolver and to evaluate of aerobic liquid-composting system. We design a new kind of high efficiency oxygen dissolver(HEOD) system. Test result of this system, Saturated DO concentration was showed that the fit condition was at 1.0 L/min2 pressurized oxygen pressure and at 0.6 kg/cm2 in pressurized water, respectively. Mass transfer of oxygen in HEOD system, the highest dissolvedoxygen concentration is as high as 56.0 mg/L in comparison of only air supply condition and pure oxygen dissolving on the system, DO dissolving level was higher about 34 mg/L in condition of oxygen supply than the air supply. The capture of bubble images was automated by commercial image analyser. The average bubble size in diameter showed that the air injection was 275 ㎛ and oxygen was 28 ㎛, respectively. And the surface area of bubble estimated that theair injection was about 21.8 m2 and oxygen was about 214.3 m2, respectively. In this result, the system efficiency in condition of pure oxygen supply was higher than the air supply, so it inquired further into liquid-composting using by oxygen dissolver.

Cited by 0 works.

Authors