면진된 비상디젤발전기의 지진취약도 분석

김민규, 大鳥靖樹, 전영선 · 한국지진공학회 춘계학술발표회 논문집 · 2007

In this study, for the evaluation of seismic safety of the isolated EDG System more quantitatively, the seismic fragility analysis method were proposed. Using the proposed method, seismic fragility analysis performed and a seismic risk of EDG system was present. The fragility analysis performed not for an existing EDG system but also for an isolated EDG system which increases the seismic capacity. The HCLPF values were evaluated for the compare the improvement effect using the isolation system. As a result, the isolation system can make better the seismic fragility of EDG system, but the failure of isolation system was govern the behavior of whole system,