건물 모형 실험을 통한 쿨루프 효과 비교

김경아, 송봉근, Seonghyun Kim et al. · 대한설비공학회 학술발표대회논문집 · 2019

This study aims to identify the effects of cool roofs by investigating building models located in Changwon that have roofs constructed of various types of materials and colors. The building model roofs were comprised of white, green, and black waterproof paints; white, green, and black asphalt shingles; and rooftop vegetation. The surface temperatures of the building model roofs were measured from May 29-August 14. To identify roof characteristics, the flow of energy from roof surfaces to the ambient air, and the amount of energy accumulated on the roofs, were investigated. Reflectivity, emissivity, weather conditions and net radiant energy were measured during 9:00–15:00 on July 31, 2014. The reflectivity and emissivity of the white waterproof painted roof and the white asphalt shingle roof, the “cool roofs,” were higher than the other roofs, and their surface temperatures and net radiant energy were lower than the other roofs. The surface temperature of the white waterproof painted roof was lower than the green and the black waterproof painted roofs by a maximum of 25℃; the surface temperature of the white asphalt shingle roof was lower than the green and the black asphalt shingle roofs by a maximum of 19℃.

Cited by 0 works.