강관기둥-강관말뚝 연결부의 내진성능 평가

오미란, 이대용 · 한국강구조학회 학술발표대회 논문집 · 2013

In order to evaluate seismic performance of the steel column-to-steel pile joint which is developed for rapid erection, an experimental study is executed. The joint is consisted of socket and adapter, and a column base plate is fixed to the top of the socket by using thigh strength bolts. A cyclic loading history which is used for the SAC Steel Project in the U.S. is applied at the top of the column specimen, and the loading amplitude(Drift) is gradually increased until the specimen fails. The test result shows that the joint can develop a certain level of structural safety, and the seismic performance can be improved by reinforcing the structural components in the joint.

Cited by 0 works.

Authors