교량용 방호울타리 지주시스템 구조성능 평가
이대용, 오미란, 김승억 · 한국강구조학회 학술발표대회 논문집 · 2011
Three systems (Type-1, Type-1A, and Type-1B) are designed for the use of steel post for bridge guardrails which are installed in downtown areas. Main design variables among these structural systems are reinforcing detail of the base plate (between Type-1 and Type-1A & Type-1B) and anchor bolt type (between Type-1A and Type-1B). In order to evaluate structural performance of the three systems and make a decision for direction of system development, an experimental study is conducted. Three 100% scale steel post specimens (one for each) are prepared for the study and the structural performances are evaluated by conducting one-point lateral bending tests. It is found that a strength increase and better performance of the system can be achieved when the base plate is properly reinforced. Also found in this experimental study is that a required structural performance as well as field constructability can be achieved by the use of high strength head-shape anchor bolts.
Cited by 0 works.