철계-형상기억합금 나선철근으로 횡구속된 콘크리트의 압축거동
지상원, 연영모, 홍기남 · 2020
This study evaluates the lateral confinement effect of a column using Fe-based shape memory alloy (Fe-SMA) spiral reinforcement. For the experiment, 150 × 150 × 300-mm cylinder specimens confined by Fe-SMA spiral reinforcement of a 4% pre-deformed 5 × 5-mm section were fabricated. Two experimental variables were considered: the pitch (0, 80, 60, and 40mm) and activation/non-activation of the Fe-SMA spiral reinforcement. To activate the Fe-SMA spiral reinforcement, the specimen was heated to the target temperature of 140° using a kiln. After the specimen was cooled to room temperature, a uniaxial compression test was performed using a universal testing machine. The experimental results confirm that the maximum stress and corresponding strain of the specimen with Fe-SMA spiral reinforcement activation were significantly increased compared with that of the specimen without activation. Additionally, it was found that, due to the decreased pitch of the spiral reinforcement, the maximum stress and ductility index increased significantly as the active lateral confinement pressure increased. In particular, it was found that the specimens confined by activated 40-mm-pitch spiral reinforcement exhibited strain hardening, which maintained and increased the load after the maximum load was reached.
Cited by 0 works.