Методы исследования давления насыщенных паров и экспериментальные установки
Харченко Павел Михайлович, Тимофеев Виталий Павлович, Чижов Даниил Сергеевич · Политематический сетевой электронный научный журнал Кубанского государственного аграрного университета · 2015
The static method is the most common, because it is applicable for measuring SVP of substances in wide ranges of temperatures and pressures. The essence of the method consists in measuring of vapor pressure in equilibrium with its liquid at a given temperature. Dynamic method is based on measurement of the boiling point of the liquid at a certain pressure. Saturation method of moving gas used in the case when the SVP does not exceed a few mm Hg. The method consists the following: the liquid is passed through the inert gas and saturated with vapor of liquids and then it flows into a cooler where the absorbed vapors are condensed. Knowing the amount of absorbed liquid and gas, as well as their molecular weight, allow us calculate saturated vapor pressure of the liquid. Knudsen effusion method is applicable for the measurement of very low pressures (up to 100 Pa). This method consists in researching of depending between the pressure and volume of saturated steam at a constant temperature. At the point of saturation an isotherm should have a break and turn into a straight line. Chromatographic method is based on complete chromatographic analysis of liquid and calculating the sum of partial pressures of all mixture components. Also, the article has a description of existing experimental installation for these researches and their advantages and disadvantages compared with each other
Cited by 0 works.