Експериментальне дослідження розвитку пожежі в будівлі
Дмитро Петрович Дубінін, Андрій Анатолійович Лісняк, Serhii Shevchenko et al. · Problems of Emergency Situations · 2021
Experimental studies on the occurrence of fire in a residential building depending on the conditions of its development. A model of the house was used for research, which allowed to clearly demonstrate the development of fire with a demonstration of its phenomena. It is determined that the development of a fire with limited access to oxygen occurs with the occurrence of fire phenomena such as rollover, flashover and backdraft, and with sufficient access to oxygen occurs normally. It is established that during the development of a fire first there is a phenomenon of rollover, due to the ignition of a layer of heated gases, then there is a flashover, characterized by a flash, and for backdraft, this phenomenon occurs due to a flash of unburned heated gases with a subsequent explosion. The temperature was measured using a FLIR K33 thermal imager during a fire. The obtained results show that the development of a fire with sufficient access of oxygen occurs before the maximum temperature in the room with its subsequent reduction due to fire extinguishing or supply of fire extinguishing agents to the fire. When a fire with limited access to oxygen develops, such phenomena as rollover, flashover and backdraft occur. The obtained measurement results during the research of fire development depending on its conditions are presented as photoregistration of images from the thermal imager and graphically. It is established that when the phenomenon of a flashover occurs, the flash point is 234 C, and when the backdraft phenomenon, the flash point of unburned heated gases with a subsequent explosion is 569 C. It has been experimentally determined that timely cooling of heated gases prevents fire. The obtained results of the conducted experimental researches allow to increase the level of professional skill of the personnel of fire and rescue divisions during carrying out operative actions on fire extinguishing in residential buildings.
Cited by 4 works. doi:10.52363/2524-0226-2021-34-8
Authors
References
- Improving the installation for fire extinguishing with finelydispersed water
- The Association of Aerobic Fitness With Injuries in the Fire Service
- Defining the Difference between Backdraft and Smoke Explosions
- Experimental investigation of the fireextinguishing system with a gasdetonation charge for fluid acceleration
- Experimental Study on the Mitigation of Backdraft in Compartment Fires with Water Mist
- An experimental study on backdraught: The dependence on temperature
- Дослідження вимог до перспективних засобів пожежогасіння тонкорозпиленою водою
- Experimental Study of Gas Cooling During Firefighting Operations
- Three Different Fire Suppression Approaches Used by Fire and Rescue Services
- DIN EN ISO 13943:2018-01, Brandschutz_- Vokabular (ISO_13943:2017); Deutsche und Englische Fassung EN_ISO_13943:2017