W4244559944

義幸 新崎, Kunio Shinohara, Tatsuo Tanaka · Journal of the Society of Powder Technology Japan · 1983

Pneumatic Escalator was examined by pulsating air from the standpoint of heat transfer operation of particles. As a result, it was found that the apparent passing velocity of solids through the device in pulsed air flow was similar to that of as constant flow and that the frequency of pulsation did not affect heat transfer as much as expected. However smaller intermittency increased the rate of heat transfer, because the average relative velocity between solids and air was enhanced as compared with the constant air velocity. Thus, similarly to other simultaneous operation of solids-gas contact, Pneumatic Escarator was confirmed to provide better heat transfer results by adding pulsation to heating air.

Cited by 0 works. doi:10.4164/sptj.20.422 Open-access PDF