CITE-seq
Marlon Stoeckius, Marlon Stoeckius, Peter Smibert · Protocol Exchange · 2017
Here we describe the protocol for Cellular Indexing of Transcriptome and Epitopes by sequencing \(CITEseq).CITE-seq combines unbiased genome-wide expression pro ling with the measurement of speci c protein markers in thousands of single cells using droplet micro uidics.We conjugate monoclonal antibodies to oligonucleotides containing unique antibody identi er sequences.We then label a cell suspension with the oligo-tagged antibodies and single cells are subsequently encapsulated into nanoliter-sized aqueous droplets in a micro uidic apparatus.In each droplet, antibody and cDNA molecules are indexed with the same unique barcode and are converted into libraries that are ampli ed independently and mixed in appropriate proportions for sequencing in the same lane.Reagents • Flow-cytometry grade monoclonal antibodies, unlabeled and puri ed • Antibody streptavidin conjugation kit \(e.g.Bio-Rad LYNX kit #LNK163STR, or, Innova Biosciences Lightning-Link kit # 708-0030) • NHS Biotinylation reagent \(e.g.Thermo, EZ-Link Sulfo-NHS-SS-Biotin, No weight format.#21328) • Centrifugal Filters 50kDa cutoff: \(e.g.Millipore Amicon Ultra -0.5mL Centrifugal Filters #UFC505024) • FC blocking reagent \(e.g.BioLegend) • Desalting columns.\(e.g.Bio-Rad, Micro Bio-Spin 6 Columns.#732-6221) • 8-strip PCR tubes, emulsion safe \(\!) \(e.g.TempAssure PCR 8-strips, USA Scienti c) •
Cited by 7 works. doi:10.1038/protex.2017.068 Open-access PDF