埋設鋼管の土壌中でのミクロ電池形成による腐食

Hidemasa Nonaka, 竹原 善一郎 · Denki Kagaku oyobi Kogyo Butsuri Kagaku · 1990

Methods to electrochemically measure the corrosion rates of steel pipes caused by the formation of micro cells in sQils were studied,CQnsequently,it was revealed that the formatiQn of rust layer on the pipe surface in soils Qbstructed the estimation of corrQsion rates based on the pQlarizatiQn curves obtained when a pQwer supply was used, and that wben cQrrosiQn rates were estimated based Qn the pQlarization resistance,reasonable results were obtained from Eq.(9)given by considering the effect of soil resistance between a local anode and a local cathode.Sulfate ions in soils promoted cor-rosion.Corrosion rates tookεしmaximum value at a certain water content. 1 緒 言 都市ガスを輸送する配管は,主として炭素鋼管が用い られているが,その大部分は土壌中に埋設されている・ この鋼管は,

Cited by 0 works. doi:10.5796/kogyobutsurikagaku.58.817 Open-access PDF