Особенности разрушаемых элементов предохранительных конструкций, используемых для минимизации последствий взрывных аварий в помещениях
А. Д. Корольченко, Н. В. Громов · Pozharovzryvobezopasnost/Fire and Explosion Safety · 2023
Introduction. The relevance of the present publication is caused by the fact that during the development of constructive decisions of safety locking devices (SLD) designers often use elements and materials, which are fundamentally not applicable for these purposes. The peculiarities of safety structures (SS) and light removable structures (LRS) used in buildings and premises where internal emergency explosion is possible are analyzed. The results of experimental studies on testing the performance of real structures are given. Obje ctive. Determination of the possibility of SS and LRS application at explosive objects, as well as restrictions on their fastening elements and used materials. Materials an d methods. Studies of LRS fixed by SLD were carried out by means of their tests on the impact of internal emergency explosion and on resistance to mechanical and wind loads (according to GOST 26602.5). Explosion tests were carried out in a cubic chamber using a propane-air mixture of stoichiometric composition. Overpressure sensors recorded explosive pressure. Video recording of the explosion process was done by speed cameras. Results. The features of safety structures used to reduce the pressure generated by internal accidental explosions were analyzed. Explosive pressure oscillograms were constructed and analyzed based on the test results. It is shown that the use of static (wind or mechanical) loads instead of explosive loads in SS performance testing can lead to significant distortion of test results. It is experimentally established that testing of specimens of safety structures for their serviceability should be carried out only by modelling of explosive load. Conclusions. Substitution of explosive loads for static loads during SS testing may lead to their failure in case of emergency explosion in real conditions, which may result in collapse of building structures and human casualties. Thus, testing of specimens of safety structures for their operability should be carried out only by modelling of explosive load.
Cited by 1 works. doi:10.22227/0869-7493.2023.32.06.69-78 Open-access PDF
Authors
References
- Observations of flame instabilities in large scale vented gas explosions
- The consideration of the turbulence influence on the gas explosion expansion in non-closed areas
- Experimental and numerical study on CFRP strip strengthened clay brick masonry walls subjected to vented gas explosions
- Analysis of the safety of residential buildings under gas explosion loads
- Effect of concentration and ignition position on vented methane–air explosions
- Vented gaseous deflagrations: Modelling of spring-loaded inertial vent covers
- A numerical study of gas explosion with progressive venting in a utility tunnel
- Experimental study on gas explosions of methane-air mixtures in a full-scale residence building
- Conditions of occurrence of fire in the room with a gas explosion. Experimental data
- Dynamic Effects at Internal Deflagration Explosions