В работе подведены итоги ресурсных испытаний детского экзоскелета медицинского назначения. Дано описание методики испытаний, экспериментальной установки, схемы проведения измерений. Приведены результаты телеметрии одного из этапов эксперимента. На основе замеров потребляемого тока в приводах произведено сравнение характера изменения крутящего момента в BLCDприводах экзоскелета и крутящего момента в суставах здорового человека. Introduction. Paper is addressed to the service life tests of medical exoskeleton for children. There is briefly discussed the method and telemetry of tests. Besides, energy costs of the exoskeleton and a person for straight walking case were obtained. Exoskeleton with a weight dummy similar in mass and dimensional characteristics to a man was mounted on a medical treadmill (conveyor belt with an adjustable drive). Exoskeleton drives were programmed with the laws of motion similar to locomotion of a straight walking man. Sensors allowed to gather data on the operation of the directcurrent motors in the exoskeleton drives at a steadystate motion. The current loads of the drives were read by the shunting method. Findings. The paper presents generalized data from sensors, telemetry data, graphs of currents and angular values observed in hinges. Successful life tests showed that, in general, the exoskeleton meets the requirements of the technical specification. After carrying out tests, we performed a comparison of the energy costs that are spent for straight walk of a person and exoskeleton. According to the fact that the kinematics of a straight walking person and exoskeleton are similar, the power (moment) loads in the drives and joints turned out to be similar. In the exoskeleton, the moment load in the drive is proportional to the electric current at the motor clips. Comparison of the load in one step cycle yielded graphs that almost satisfy the data on the change in moments in the knees and hip joints of a man according to D. Winter. It has been taken into account that an exoskeleton with a more rigid structure exhibits rougher motions when stepping. It leads to the striking reaction that gives rise to oscillating motion and vibrations. The effect influences power (moment) characteristic of walking. Practical significance. The outcomes of the analysis could be applied for developing methods of myostimulation of the muscles of the patient legs, because it is directly related to the occurrence of a moment in the joints of a man.
Cited by 0 works. doi:10.25686/2306-2819.2019.3.41