W588326112
ETSUKO IKEDA, 山本 一彦, Haruhiro Noguchi et al. · The Japanese Journal of Jaw Deformities · 2001
The study examined the stability of a bioabsorbable osteosynthesis system after surgical correction of jaw deformity. Nine patients received sagittal splitting ramus osteotomy (SSRO), fixed with a bioabsorbable poly-L-lactide (PLLA) osteosynthesis system. Of these, three received simultaneous Le Fort I osteotomy. A control group, of eleven patients, received SSRO. Of these, six received simultaneous Le Fort I osteotomy, fixed titanium plates, and screws. Stability after surgery was analyzed cephalometrically. There was no significant difference in postoperative stability between the two groups, not only in cases of SSRO alone but also in cases of SSRO with Le Fort I osteotomy. These results indicate that the PLLA osteosynthesis system can be used effectively in surgery for jaw deformity.
Cited by 2 works. doi:10.5927/jjjd1991.11.91 Open-access PDF
Authors
References
- Foreign-body reactions to fracture fixation implants of biodegradable synthetic polymers
- Ankle Fractures Treated Using Biodegradable Internal Fixation
- Resorbable Plate Fixation in Pediatric Craniofacial Surgery
- A bioabsorbable poly-L-lactide miniplate and screw system for osteosynthesis in oral and maxillofacial surgery
- Skeletal stability following mandibular advancement and rigid fixation with polylactide biodegradable screws
- Stability after surgical correction of mandibular prognathism using the sagittal split ramus osteotomy and fixation with poly-L-lactic acid (PLLA) screws
- Osteotomy site healing following mandibular sagittal split osteotomy and rigid fixation with polylactide biodegradable screws
- Biodegradable osteosynthesis in mandibular advancement: a pilot study