Энергоэффективное нагружение асинхронных электродвигателей в процессе послеремонтных испытаний

А. А. Марченко, Н. Н. Портнягин · CyberLeninK (CyberLeninka) · 2014

In article offered methods on loading of asynchronous electric motors after repair by current and the moment. This technique has advantages. Instead of tests by means of mechanical loading with connection of additional machines on a shaft of the examinee of the electric motor it is offered to use the dynamic modes of the machine, that will allow to refuse mechanical connections. Change of frequency of tension directly influences the moment on a shaft of the machine and electric motor current. Applying these properties it is possible to receive value of an average power on a shaft that is necessary at test of machines after repair. Also this technique assumes recovery of the electric power. For confirmation of the declared technique authors bring results of modeling of this process. The presented materials visually confirm expediency of use of the lowered frequency of 25 Hz, in this mode received the greatest value of power on a shaft of the machine and the power given to a network is. It is offered to apply two schemes depending on requirements to energy efficiency of system.

Cited by 0 works.

Authors