Методика и результаты оптимизации параметров системы обдува ограждений варочного бассейна стекловаренных печей

Б. А. Семёнов, Н. А. Озеров · Вестник Саратовского государственного технического университета · 2011

The new method of technical and economic calculation is based on the previously developed mathematical model of process of high-temperature corrosion of fire-resistant walls of the melter part of glass furnaces. It allows to prove economically expedient air speed in the air cooling system of external surfaces of tin-baths. The calculation is based on the example glass furnace of Open Society SaratovStroySteklo with the prices as of 2012 which allows to assert that realization of economically expedient speed of air cooling, used instead of the actual speed value now at 45 m/s, provides prolongation of service life of a technological line by approximately 1 year, and an increase of the pure discounted income of an enterprise by 640 million rubles. Moreover, as a result of the use of wall facings of tin-bath fire-resistant tiles of the minimum thickness additional increment PDI at the rate of 360 million rubles can be achieved.

Cited by 0 works.