Определение уровня Д-димеров в диагностике и оценке эффективности терапии акушерского синдрома диссеминированного внутрисосудистого свертывания
Н. А. Оганесян, Л. С. Бут-гусаим, Ю. В. Киселевский et al. · Журнал Гродненского государственного медицинского университета · 2006
The study is aimed at evaluating the importance of D-dimers determination in diagnostics and at evaluating DIC syndrome treatment efficiency in obstetric patients. It has been demonstrated that D-dimers test is the most sensible and specific laboratory test in diagnostics of DIC syndrome especially at early stage of its development and it can also be effectively applied as the therapy effectiveness criterion in case of such a complication. The aim of the study was to evaluate efficiency of application of evaluation of D-dimer levels for early diagnostics and evaluation of DIC syndrome treatment efficiency in obstetric patients. Methods and materials: 127 patients with high risk of DIC have been examined. They have been divided into three subgroups: 81 patients in which the diagnosis was excluded, 31 patients with DIC I and 17 patients with DIC III. D-dimers were determined by immunometric technique. The evaluation of the test has been conducted applying ROC-curves and analysis of indices informativity. Results obtained: routine coagulological tests (APTT, INR, fibrinogen, platelets) tend to be low sensitive for early stages of DIC. Determination of D-dimers in the group with the risk of DIC enables to effectively reveal this pathology at hypercoagulation stage (DIC I). Besides D-dimer test can be effectively applied as an early marker of DIC syndrome therapy effectiveness. Conclusions: 1) D-dimers level is an effective DIC syndrome marker at hypercoagulation stage in the group of patients with obstetric complications. Concentration of D-dimers 2.5mg/l is the diagnostic criterion. 2) D-dimers test is a significant and informative index diagnostics of DIC syndrome at DIC II-III stage in the group of patients with obstetric complications. D-dimers level comprising 5mg/l is treated as a diagnostic threshold. 3) Evaluation of D-dimers concentration can serve as an evaluation marker of obstetric DIC syndrome therapy efficiency. Optimal time of repeated D-dimers level measurements aiming at control of DIC syndrome therapy effectiveness comprises 3-6 hours. The optimal criterion enabling to treat therapy as a successful one is reduction of D-dimers level by 40 and more per cent in 3-6 hours of therapy.
Cited by 0 works.