低凝固点油滴の凝固を利用した潜熱蓄冷に関する基礎研究 第2報 低温水溶液中を浮上するテトラデカン油滴の凝固および熱伝達の無次元整理式

英男 稲葉, 憲二 佐藤 · Institutional Repositories DataBase (IRDB) · 1996

The latent cold heat storage system using the direct-contact freezer with tetradecane oil and ethylene glycol aqueous solution as the latent cold heat storage material and the cold heat transfer medium, respectively, was proposed in a previous paper [Inaba and Sato, Trans. JSME, 60-580 (1994), 4236.]. In this report, in order to obtain practical data for industrial application, nondimensional analysis of the solidification rate of the tetradecane oil droplets and the overall heat transfer coefficient in the freezer was carried out. In this system, the tetradecane oil droplets change from liquid to solid state during ascension in the cold heat transfer medium. Therefore, liquid-liquid and solid-liquid coexisting-type direct-contact heat transfer occurs between the tetradecane oil droplets and the aqueous solution. It can be considered that the flow pattern and heat transfer process are different for the liquid-liquid and the solid-liquid systems. The empirical equations of the solidification rate and the overall heat transfer coefficient were derived for the averaged values for the entire freezer. The optimum operating conditions at which the maximum solidification rate can be achieved were clarified.

Cited by 0 works. Open-access PDF

Authors