Изменения внутрипочечного кровотока при ортостатической пробе у больных артериальной гипертензией

Мельникова Людмила Владимировна, Бартош Леонид Федорович · Kazan medical journal · 2011

Aim. To study the the dynamics of dopler characteristics of blood flow in the interlobar renal arteries in hypertensive patients during the orthostatic test. Methods. Examined were 86 patients with hypertension, in whom the parameters of intrarenal blood flow (systolic and diastolic velocity, acceleration time) and central hemodynamics (specific peripheral resistance, cardiac index) were determined with the help of ultrasound investigation. Patients were divided into two groups according to the reaction of acceleration time during the orthostatic test. Results. It was revealed that patients with prolonged acceleration time showed signs of reducing the mechanical compliance of renal arterioles and disturbances of self-regulation mechanisms of renal blood flow. Conclusions. Lengthening the acceleration time during the orthostatic test in patients with hypertension indicates a possible disturbance of the mechanisms of autoregulation of renal blood flow and requires more careful investigation of the renal function in a particular patient.

Cited by 0 works.

Authors