Способ и устройство идентификации самонагревания угля в шахтах
Портола Вячеслав Алексеевич, Лабукин Сергей Николаевич · Вестник Кузбасского государственного технического университета · 2009
The article concerns the results of laboratorial tests of device developed for detection of coal self-heating based on total content of steam and liquid aerosol in the mine air. The rate of air filtration through the sorbent to maximize steam and aerosol recovery is determined. This study found the temperature dependence of quantity of generated aerosol when air passes through heated coal.