ОЦІНЮВАННЯ ВІДТВОРЮВАНОСТІ РЕЗУЛЬТАТІВ ВИПРОБУВАНЬ ІНФОРМАЦІЙНО-ВИМІРЮВАЛЬНОЇ СИСТЕМИ ДЛЯ ВИМІРЮВАННЯ ГЕОМЕТРИЧНИХ ПАРАМЕТРІВ ФУНКЦІОНАЛЬНИХ МІКРОСТРУКТУР

Vitalii Andreiko, Ігор Жайворонок, Serhii Matsepa et al. · The Scientific Issues of Ternopil Volodymyr Hnatiuk National Pedagogical University Series pedagogy · 2025

The article focuses on the key property of such information and measurement systems (ISS), namely: the ability to give stable results under changes in conditions and performers. After all, it is reproducibility that determines the credibility of the measured parameters and the possibility of their practical use. The formulation of the problem of the article was based on the fact that when studying microstructures, it is necessary to observe numerically justified limits of permissible discrepancies between laboratories for complexes combining scanning probes, measuring electronics and software processing modules. Analysis of previous studies showed that existing work was mostly limited to in-laboratory repeatability checks and did not provide interlaboratory evidence of consistency for integrated IVS, and rarely offered transparent acceptance criteria for quality control. The purpose of the work is to quantify the reproducibility of IVS test results and establish understandable threshold values for further validation of microstructure measurements. Two independent series of 32 measurements were performed in two laboratories on a control test sample using scanning probe microscopy and the IVS developed on the basis of the NT-206 device. The resulting protocols were harmonized and the measurement order randomized. The calibration of the standard, its statistical processing included the isolation of the laboratory factor, the estimation of the variances of the components and the construction of 95% of the agreement limits. For both series of samples, the same average value of surface microgeometry at 10.48 nm was obtained. The sums of the squares of the deviations were, respectively, 0.0512 and 0.0480 with a variance of interserial reproducibility of 0.0032 and a standard deviation of 0.056. At the same time, the marginal difference at 95% confidence is R = 0.155, while the maximum observed difference between laboratories is 0.08 (residue distributions are normal, trends in the order of measurements and systematic shift were not detected). As a result of the tests, the results obtained at the IVS are stable and metrologically compatible between laboratories. The proposed procedure for assessing reproducibility is suitable for inclusion in validation regulations, and the established threshold values can serve as a basis for regular interlaboratory control and scaling to other parameters and measurement scenarios in the development and study of functional microstructures.

Cited by 0 works.

Authors