ПІДВИЩЕННЯ ТОЧНОСТІ ЄМНІСНОГО ВИМІРЮВАЧА ПОВІТРЯНОГО ПРОМІЖКУ МІЖ СТАТОРОМ ТА РОТОРОМ У ГІДРОГЕНЕРАТОРАХ НА ОСНОВІ ДИФЕРЕНЦІАЛЬНОГО МЕТОДУ

Левицький , Анатолій, Євген Зайцев, Sergy Zakusilo · The Scientific Issues of Ternopil Volodymyr Hnatiuk National Pedagogical University Series pedagogy · 2025

The air gap (AG) between the stator and rotor of the hydrogenerator (GG) has a strong influence on the formation of the electromagnetic field of the machine, therefore its nominal value must be maintained with high accuracy. Deviation of this value can cause a decrease in the dynamic stability and reliability of the unit. Therefore, there is a need for constant monitoring of the air gap both during the operation of the GG and during inspections and repairs using effective modern measurement and diagnostic methods. The purpose of this article is to create and study the capacitive meter (CM) AG, which, in comparison with analogues, provides higher measurement accuracy. The main functional parts of the proposed EV are the capacitive sensor (CS), the measurement unit (MU), which is used as a secondary measuring transducer, and connecting cables. CS consists of variable and constant measuring capacitors, and the informative parameter CM is the ratio of the capacitances of these capacitors, which makes it possible to eliminate the influence on the accuracy of measurement of changes in the parameters of the air environment surrounding the CS: temperature and relative humidity. The structural scheme of the CS is described, which is proposed for implementation as a multilayer printed circuit board with thin conductive and dielectric layers. The electrodes of the variable and constant measuring capacitors, as well as shielding surfaces, are formed in the conductive layers. It is noted that to ensure the optimal EV conversion function, the electrical capacitance of the constant capacitor should be equal to the capacitance of the variable capacitor in the middle of its measurement range. To eliminate the influence of edge effects, the flat active electrode of the variable capacitor is surrounded around the perimeter by a flat guard electrode, the potential of which is equal to the potential of the active electrode, but they are not galvanically connected to each other. In this case, the variable measuring capacitor is connected to the measuring unit by a cable with a double shield, in which the central core is connected to the active electrode, the inner shield to the protective electrode, and the outer to the ground. Analytical dependencies are determined for the CM AG conversion function, intended for use on GG of any type. The graph of the EV conversion function, intended for use on GG of type SV 1230/140-56, is shown. The meter can be used as a separate device, or as a component of GG monitoring and diagnostic systems.

Cited by 0 works.

Authors