ВИЗНАЧЕННЯ ВІДСТАНІ ВІД ВИПУСКУ СТІЧНИХ ВОД У МОРСЬКЕ СЕРЕДОВИЩЕ ДО КОНТРОЛЬНОЇ ТОЧКИ ПРИ ОЦІНЦІ ТЕХНОГЕННОГО ВПЛИВУ НА ДОВКІЛЛЯ

Олег Аскольдович Проскурнин, О.О. Дем’янова, Ірина Валентинівна Кирпичова et al. · Scientific Bulletin of Civil Engineering · 2025

The article is devoted to the choice of the distance to the control point when assessing the local impact of wastewater discharge on the state of the marine ecosystem. It is noted that, in general, the methodology for assessing the local impact of point sources of pollution was developed in the first decade of this century. Existing approaches to determining the technogenic impact on water bodies are based on a comparison of the estimated concentrations of pollutants in natural water with the standards of maximum permissible concentrations. In this case, limiting signs of harmfulness of substances (i.e. when different substances cause similar harm to living organisms) can be considered, as well as weighting factors that reflect the cost of water protection measures when damaging the ecosystem with specific substances. It is noted that the choice of the distance from the wastewater outlet to the control point remains an unresolved issue. The problem is especially acute for deep-sea wastewater outlets. In this case, at a small distance from the control point to the outlet, the sea surface may remain unpolluted (since the wastewater is at sea depth), which will lead to an underestimated estimate of the anthropogenic impact of the discharge. The authors of the article propose to use mathematical modeling methods to determine the distance at which significant mixing of wastewater and seawater occurs vertically. And to set a control point at this distance. It is proposed to use a numerical solution of the turbulent diffusion equation for a stationary case for this purpose. In this case, the proposed calculation formula, unlike the existing formula for watercourses, is obtained taking into account different values of the coefficients of vertical and horizontal turbulent diffusion. A demonstration example of assessing the impact of municipal wastewater discharge from Genichesk (Kherson region) through a deep-water outlet on the state of the water of the Sea of Azov in the area of the outlet is given. This example illustrates the erroneousness of setting a control point at a short distance (50 m), since relatively complete mixing of wastewater and seawater vertically occurs at a distance of about 400 m from the outlet.

Cited by 0 works. doi:10.33042/2311-7257.2025.113.1.33 Open-access PDF

Authors