液充満式かきとり面形熱交換器内の熱伝達

尚 宮下, 安明 塚田, 寛 延対寺 et al. · Institutional Repositories DataBase (IRDB) · 1979

A problem flequently encountered in chemical industry is the cooling (heating) of a viscous fluid or solid-fluid system in such a manner that a continuous flow of uniform product is obtained. Therefore scraped surface heat exchanger is often used to process high viscous and/or thermally unstable materials.In this work, the time-avereged local heat transfer coefficients in a liquid-full scraped surface heat exchanger have been investigated on experiment, using the electrochemical method of redox system, for two- bladed exchanger, and they have been compared with those predicted by the conduction model based on unsteady state condition.As the result, the following equation was correlated. Nu=1.18(Re_r)^<0.5> (Pr)^<0.5> This equation have agreed with the conduction model and other experiments in an agitated vessel with two blades of anchor type within the experimental errors.

Cited by 0 works. doi:10.15099/00004225 Open-access PDF