上下顎骨骨切り術中に経鼻栄養チューブが損傷された1 例
Akira Ukai, ひかる 名知, 高広 上野 et al. · Institutional Repositories DataBase (IRDB) · 2025
We experienced a case of nasogastric feeding tube was damaged during maxillo-mandibular osteotomy. A 21-year-old male, had undergone a total of seven facial plastic surgeries at other hospitals due to multiple facial fractures caused by trauma at the age of 3 years. This time, Le Fort I osteotomy and sagittal split ramus osteotomy were scheduled to improve the inferior growth and occlusion of the midface. After induction of anesthesia, a 60 cm nasogastric feeding tube was inserted through the left nostril for postoperative nutrition. We removed about 5 cm of the tube because it was placed in a slightly deeper position on radiographs. The tube was partially damaged, and we carefully removed it completely with forceps to avoid cutting the tube. In addition, when the nasogastric feeding tube is damaged, there is a possibility of aspiration, residual tube, rupture, and wound infection, and we discussed early detection and protective measures against these risks. The nasal cavity length is approximately 6.5 cm-7.5cm long, it is highly likely that tube damaged will occur within 10 cm of the external nostril. The usual clinical insertion length of a nasogastric feeding tube is the NEX (nose-ear-xiphoid measurement) plus 10 cm, and the countermeasure is to insert the tube 10 cm longer than the NEX plus 10 cm before surgery, and to pull it out 10 cm before confirming it on postoperative radiographs. We thought that the damage to the tube could be confirmed by pulling out the tube 10 cm before checking the postoperative radiographs.
Cited by 0 works. doi:10.15090/0002000461 Open-access PDF