吹雪量測定に及ぼす昇華の影響について-ネット式吹雪計の場合-

佐藤 威 · Institutional Repositories DataBase (IRDB) · 1991

Theoretical calculations and measurements in a cold room were carried out for the sublimation rate of col1ected b1owing snow in a Net type conector. The calcuIations based on the heat baIance of collected snow showed the dependency of the sublimation rate on the temperature and relative humidity of the air,the transfer coefficient for sensib1e heat(which is close to that for water vapor),and R一σT4(R is the energy input to the collected snow and T is the air temperature).The dependence on each parameter is similar to that of a Cyc1one type col1ector,as revea1ed by Sato( 1990). The measured sublimation rates increase with the len就h of the collected snow up to about four times as1arge as those for the Cyclone type conector mder similar experimenta1conditions.Taking account of the difference in the in1et area between the two type collectors,however,the sublimation of collected snow is not serious in the mass f1ux measurement with the Net type collector as compared to the Cyclone type one. The transfer coefficient for sensib1e heat(water vapor)was obtained from measured sublimation rates and experimenta1conditions.The transfer coefficient increases with the increase of the1ength of collected snow,partIy due to the sublimation from the side of it.The transfer coefficient also increases as the ambient wind becomes strong,and it decreases as the co1lected snow becomes dense. Considering these properties of the transfer coefficient,schematic diagrams were presented to give the sublimation rate of co11ected blowing snow under various meteorological conditions(air temperature,ambient wind speed,and relative humidity). Key wo皿止:Blowing snow,Blowing snow collector,Net type col1ector,Sublimation rate,Mass f1ux of b1owing snow キーワード 地吹雪,吹雪計,ネット式吹雪計,昇華量,吹雪量

Cited by 0 works. doi:10.24732/nied.00001015 Open-access PDF

Authors