隣接線影響に基づいた故障検出・診断のためのテスト生成法に関する研究

淳 山下 · Institutional Repositories DataBase (IRDB) · 2015

In recent IC, testing open faults become important.On the basis of defect condition, these are classified into full open faults and resistive open faults.The full open fault is disconnected from its driven line.The voltage at the floating part of disconnected from its driven line is depends on the trapped charge and the effect of adjacent lines.The resistive open fault is partially disconnected from its driven line.In the presence of a resistive open fault, the additional small delay occurs at the faulty line.The open faults are difficult to test by the test patterns from the conventional stuck-at fault model.In this paper, we propose two types of test generation methods for detecting full open faults and resistive open faults.For the full open fault, we generate a test patterns that assigns logic value α to as many adjacent line as possible to excite the faulty effect at the floating line as the stuck-at α fault.