ナトリウム微少漏洩検出器耐久試験

島 孝充, 等 荒木, 宇野 修 et al. · Institutional Repositories DataBase (IRDB) · 1982

It was already confirmed that SID (Sodium lionization Detector) and DPD (Differential Pressure Detector) type sodium leak detectors for LMFBR "MONJU" had enough detection sensitivity. But an endurance test was required for putting them to practical use. Especially, life time of filament for the sodium aerosol ionization in the SID had to be examined. So, endurance performance of SID and DPD were investigated during about one year using an experimental equipment which simulates nitrogen atmosphere of reactor primary loop and sodium aerosal sampling tube. Results oftained in this test are as follows ; (1)SID filament did not break during one year operation, and little change of detection sensitivity was observed. (2)Neither performance deterioration nor measurement circuit trouble was experienced on the DPD.

Cited by 0 works. Open-access PDF

Authors