超音波洗浄法の研究
広幸 木村, 芳郎 堀, 尚武 岡本 et al. · Institutional Repositories DataBase (IRDB) · 1983
This studies were examined on the application of method using painted test pieces and sound pressure detector in order to establish a quantitative evaluation of ultrasonic cleaning property at elevated pressure. The frequency of ultrasonic transducer is 28 kHz (horn type; 19 kHz), and the generator power is max. 500W. The following results are obtained. (1) Both "the method with painted test pieces" and "the method with sound pressure detector" can apply sufficient to evaluation of ultrasonic cleaning efficiency, especially the latter is effectively for its simplicity. (2) The ultrasonic cleaning efficiency at elevated pressure decreased with increasing of static pressure.
Cited by 0 works. Open-access PDF