油圧式模擬負荷系の有用性評価

光栄 池谷, Mitsuei IKEYA · Institutional Repositories DataBase (IRDB) · 1975

The feasibility of an analog loading system utilizing a hydraulic servo valve of the pressure control type was evaluated. The results of the first study showed that the system had excellent applicability, but prototype system encountered a drawback in that the system had a relatively low frequency limit, fA, for practical use. To investigate this problem, simulation studies on a digital computer were carried out and the results indicate a high dependency of fA on the time constant of the servo valve, which is also experimentally confirmed. Based on this evaluation, it is shown that the frequency limit, fA, can be made 10Hz or higher. In addition, the results will provide useful data for the fundamental design of the analog loading system.

Cited by 0 works. Open-access PDF

Authors