電磁度数計の動作特性改善に関する一考察(その2)

茂 尾山, 正 近野 · Institutional Repositories DataBase (IRDB) · 1971

Various experimental results in order to shorten the time of operation on the electromagnetic counters are dealt with. The length of air gap between the heel-piece and the armature of counter Type XE402 is kept constant. Counter Type YE402 is made of non-annealing and has the same specification as Type E402 made of annealing material First, the dynamic operation characteristics of Type XE402 and YE402 are compared with those of Type E402. The operating time of XE402 is shorter about 13% than that of E402, and YE402 has almost the same operating characteristics as E402. Accordingly, it can be said that the operating time is not effect by annealing. Secondly, some methods of improvements on dynamic characteristics by modifying the electrical circuit are mentioned. The circuit consists of a resistance (R) and a condenser (C), or these (R,C) and a supplemental winding. By these methods, the operating time can be shorten about 14-37%.

Cited by 0 works.