機器配管系支持部及び結合部の耐震性評価に関する研究報告書(第1報 配管系の流体連成振動実験)
小川 信行, 箕輪 親宏, 敏郎 千葉 et al. · Institutional Repositories DataBase (IRDB) · 1989
In recent years,it has been pointed out mainly by theoretica1methods that1iquid in a large piping behaves dynamical1y during earthquakes and a lumped mass mode1of liquid would give a non exact piping response in some conditions. However,there has not been any comparison of theoretica1and experimental results of a real piping system,So,the authors have conducted a1arge sca1e shaking table test of a piping mode1.A test piping system,which is40m in length and254mm in imer diameter,was supported by two main and some auxiliary frame structures on the shaking table.A part of piping system was extended outside of the shaking table, and supported by uniaxial smooth sliding supports.In this experiment,some test conditions for intemal liquid were considered as the fol1owings. ‡第3研究部, 原子力事業部技術開発部 ‡刈元)石川島播磨重工業株式会社原子力事業部技術開発部 .} ‡ ‡(元)国立防災科学技術センター第4研究部 機器配管系支持部及び結合部の耐震性評価に関する研究一小川ほか 1.はじめに(研究の全体計画) 原子力施設の耐震研究は地震動,地盤,建屋,機器系等の各対象について行われるが,特 に機器配管系はそのレイアウト,支持方法および地震動の入力機構が建屋等に依存するとこ ろが多く,耐震設計に関係する問題点は多岐にわたっている。今後耐震信頼性のより一層の 向上を図る上で,これらの問題点を究明し,より合理的な設計・解析手法を確立していくこ とが重要とされている。 このような観点から,国立防災科学技術セソターでは昭和57-61年度に原子力配管に関す る実験研究を実施し,配管系の多入力地震応答解析法の検証,劣化部を有する立体配管の耐 震安全裕度の評価などを行なってきた。(小川他(1987),(1989)
Cited by 0 works. Open-access PDF