ボルタムメトリー法によるフレッシュコンクリート中の塩分含有量測定試験
明文 山田, 和範 程内, 皓一 加藤 et al. · Institutional Repositories DataBase (IRDB) · 1986
A voltammetric sensor was applied to the analysis of chloride content in fresh concrete samples. The oxidation currents at the silver electrode were monitored as a function of the time. A number of fresh concrete samples were prepared and tested with varying chloride contents (0 \sim\ 0.1 % NaCl for sand weight) and slump. The voltammetric results were in good agreement with those obtained by conventional Volhard titration methods. The effect of air-entrapping agents on chloride determination was also examined and found to be of no consequence. The chloride content can ve determined quickly by comparing the measured currents with data contained in a previously prepared working curve, which is stored in the computer’s memory.
Cited by 0 works.