In order to examine the seismic behavior of Japanese traditional temple gates to intense earthquakes, we have conducted shaking table tests using a 1/3 scale model of Eiheiji-Sanmon in Fukui pref.The bottoms of the columns of this gate are not connected to the foundation.This is one of the most important features of Japanese traditional wooden buildings.In additional to this, we inserted ultra high molecular weight polyethylene between the foundation and the bottom of the columns.The purpose of the investigation is to control low friction coefficient between the foundation and the bottom of the columns.As a result, it becomes possible for the upper frame to move from the foundation and reduce the damage of the upper frame in the event of a strong earthquake.The results from the examination are as follows (1) We evaluated Vibrational Characteristics and Damping Properties by several test methods.(2) By inserting ultra high molecular weight polyethylene, the input energy was dissipated through a sliding motion between foundation and the bottom of the columns.The damage of the upper frame was reduced.