「ふげん」燃料被覆管を用いた人工海水浸漬試験及び強度特性評価
Ichiro Yamagata, Takehiro Hayashi, 益子 真一 et al. · Institutional Repositories DataBase (IRDB) · 2013
In the accident of the Fukushima Daiichi Nuclear Power Plant of Tokyo Electric Power Co. accompanying the Great East Japan Earthquake, fuel assemblies kept in the spent fuel pool of reactor units 1-4, were exposed to the inconceivable environment such as falling and mixing of rubble, especially seawater were injected into unit 2-4. In order to evaluate the integrity of the fuel assemblies in spent fuel pools, and in the long-term storage after transported to the common storage pool, the immersion tests were performed using zircaloy-2 fuel cladding tubes irradiated in the advanced thermal reactor Fugen. The immersion liquid was prepared with doubling dilution of artificial seawater, which temperature was 80 $^{\circ}$C and immersion time was about 336 hours, as assuming the situation of the pool. The results indicated zircaloy-2 cladding tubes had no significant corrosion and no influence on mechanical property by immersion tests with artificial seawater conditions of this work.
Cited by 0 works. Open-access PDF