高速炉蒸気発生器伝熱管の中リーク・ウェステージ破損試験
田辺 裕美, 綿見 正和, 山田 敏雄 et al. · Institutional Repositories DataBase (IRDB) · 1980
A series of intermediate leak wastage tests were conducted using Large Leak Sodium-Water Reaction Test Rig (SWAT-1) at O-arai Engineering Center. The purpose of these tests was to clarify the mechanism of failure propagation to adjacent heat transfer tubes due to the flame jet of leak water in the steam generator of LMFBR. Then the value of the design basis leak for the steam generator should be proposed. The wastage rate, the size of secondary failure, and the multi-tube wastage phenomenon were mainly discussed on the basis of eleven test results, in which the water leak rate was in the range of 10$\sim$200 g/sec. Findings are as follows ; (1)The wastage rate depends on L/D (L: nozzle to target distance, D : nozzle diameter) and has a maximum value of 7 $\times$ 10$^{-2}$ mm/sec at L/D=20$\sim$30. (2)The time of secondary failure occurring in the tube bunk structure does not depend on the water leak rate. (3)The maximum diameter of the penetration hole obtained in these tests was 19mm$\phi$. (4)The dominant mechanism of the failure propagation is not overheating but wastage in the intermediate leak region. (5)The extent of multi-tube wastage increases with the increasing leak rate. Six tubes were damaged considerably at the leak rate of 200 g/sec.