交流電源より励磁した同期電動機の運転特性

隆夫 大内 · Institutional Repositories DataBase (IRDB) · 1960

This report presents how the single phase rectifier circuit will be effected on the operational characteristics, when the circuit is used as the exciter of the synchronous motor. In this case as the reactance of the synchronous motor D.C. field is too large, the rectified current is not enough for excitaion. To remedy it, the condenser is connected parallel to the field winding and d.c. current with a little ripple can be supplied to the field to excite the synchronous motor. The author compared and discussed, from the point of view of the practical use, V-curves, power factors, efficiencies of the synchronous motor excited by the single phase rectifier voltage with those of the excitation by D.C. generator. Wave forms of voltage and current were shown in both cases.

Cited by 0 works.

Authors