水中の微量低級ハロゲン化炭化水素の溶媒抽出分析法に関する研究
正憲 猪子, 建夫 谷合, 正年 土屋 et al. · Yokohama National University Repository (Yokohama National University) · 1979
A modified method for determining trace amounts of lower halogenated hydrocarbons in drinking water has been studied. Sample solution (45ml) containing more than 5mg/l of CH C13, CHCl: CCl2, CHBrCl2, CHCIBr2 and CCl2: CCl2 and 0.4mg/l of CCl4 and CHBr3 were extracted with 5ml xylene. The equilibrium concentrations of the lower halogenated hydrocarbons in xylene phase were determined by gas chromatography using an electron capture detector and the column which consists of TCP (90cm), Squalane (170cm) and Silicone DC 200 (40cm). According to this method, the ppb levels of lower halogenated hydrocarbons in drinking water were determined successfully.
Cited by 0 works. Open-access PDF