機器配管系支持部及び結合部の耐震性評価に関する研究報告書(第2報 付加ばね・質量系を有する円筒容器の振動実験)

箕輪 親宏, 小川 信行, 敏郎 千葉 et al. · Institutional Repositories DataBase (IRDB) · 1990

Piping systems are necessarily comected to the side wall of a tank for chemica1and nucIear power p1ants.In the aseismic design of the plants,however,it is common way to neg1ect the effects of such piping systems,because of its sma11mass ratio to the tank.In order to clarify these effects on the responses oftanks,shakingtabletestshavebeenconducted.Athincy1indrica1tankwith a spring-mass system prepared as a model for a simple piping system. In this shaking table test,it becomes evident that vibration of tank and spring・mass system interacts each other.The change of tank water heightinfluences the behavior of a spring-mass.The natura1frequeny differences with water height changes have been verified by computer eigen value ana1yses. Furthemore,damage pattems around thejmcture are obsemed.

Cited by 0 works. Open-access PDF

Authors