電気比抵抗を利用した杭周固定液の一軸圧縮強さの予測
舒翼 戴, 衛 藤井 · Institutional Repositories DataBase (IRDB)
Bored precast piles are commonly used to support the foundation of buildings in soft ground.The supporting performance is influenced by the quality of the circumference-fixing liquid and the foot protection liquid.The principle method used to control the quality of the solidification liquid is to check the strength of the specimen at 28-days.However, it is desirable to predict the strength at a young age.Therefore, we tried to predict the unconfined compressive strength at 28-days using the young strength and electrical resistivity at 1-day.In this study, we measured the unconfined compressive strength and the electrical resistivity at 1, 2, 3, 7, 14 and 28 days and investigated the correlation between the strength and electrical resistivity.As a result, we proposed a method for predicting compressive strength using electrical resistivity.
Cited by 0 works. Open-access PDF