ナトリウムサンプラー中の放射性核種の拳動

鈴木 実, 秋山 孝夫, 高荷 智 · Institutional Repositories DataBase (IRDB) · 1985

Sodium sampling in JOYO, Experimental Fast Reactor, has been done by methods of flow through sampler and dip tube, one the former is used for purity control of the primary sodium, study was made on behavior of radionuclides in those sampling and following observations were obtained. (1)$^{22}$Na and $^{110m}$Ag were distributed homogeneously in longitudinal sampler sodium but a few percentage of $^{110m}$Ag were diffused on the wall of sampling tube. (2)Most of $^{54}$Mn, $^{58}$Co, $^{60}$Co, $^{65}$Zn and $^{124}$Sb, or rarely $^{51}$Cr and $^{59}$Fe were found on the wall of sampling tube. It was concluded that substances in sodium were moved, deposited and diffused to the tube wall during flushing by sodium or cooling after flushing. (3)$^{58}$Co, and $^{60}$Co had tendency to increase deposit on the wall of sampling tube in proportion to sodium flow time. (4)Depth of penetration in to the wall of sampling tube were approximately 10$\sim$20$\mu$m for $^{54}$Mn, $^{58}$C0, $^{60}$Co and $^{110m}$Ag less than a few $\mu$m for $^{65}$Zn, $^{124}$Sb, $^{51}$Cr and $^{59}$Fe. From above observations, regarding $^{22}$Na and $^{110m}$Ag it is possible to analyze by using present sampling method. However concerning other radioactive nuclides, amount of each nuclide in the sampler should be determined by calculation, that is summation of amount in the sodium and one in the sampler tube wall. As for flow through sampler, it is necessary to shorten the flushing time as possible in order to analyze radioactive nuclide in sodium. Suitable sampling methods are to be developed here after.