共同利用型バイオガスプラントのエネルギー利用方法に関するライフサイクル的評価
博敬 中山 · Institutional Repositories DataBase (IRDB)
I. Introduction As the number of dairy cattle per dairy farm increases in Hokkaido, an appropriate treatment of liquid feces and urine generated at cowsheds is essential. One of the facilities that treat such a liquid manure is a methane (anaerobic) fermentation-based biogas plant. It is the site where feces and urine is fermented under an anaerobic condition with a certain temperature. After fermentation, digested slurry left over is spread over fields as fertilizer. In the course of fermentation, organic matters are bio-decomposed into gas, which can be used as energy. There are many biogas plants operated in Europe. In those plants, the combined heat and power (CHP) system converts biogas into electricity to sell to power companies and households. Thermal energy is used under the local heating network. Biogas is also purified to use as fuel for natural gas vehicle. In Japan, Hokkaido leads the country's biogas plant operation. The form of biogas utilization is categorized into using heat converted by gas boiler, and using both heat and electricity generated by CHP system. In addition, a portable equipment has developed to purify, compress and replenish biogas, which has been tested to demonstrate that the purified gas can be used for natural gas vehicle and gas burners. Biogas can be treated by gas-boiler, CHP system and purification equipment. However, there are no previous reports that assess those three forms of biogas utilization by comparing their energy productive efficiency. In this paper, the authors have conducted a life cycle assessment of the productive and economic efficiency of biogas between the three forms of utilization (gas boiling, CHP system and purification), given that biogas is used in centralized biogas plants in cold regions. We particularly focused on the following objectives: (1) to establish a program in which biogas plant operation is simulated, calculate the energy balance of biogas under the cold climate of Hokkaido, and clarify the energy volume and energy productive efficiency of biogas utilized in each form; (2) to clarify the energy balance of biogas utilized in each form in consideration of the energy volume required for plant construction and maintenance, and conduct a life cycle assessment of each energy utilization system; (3) to conduct a life cycle assessment of biogas' economic efficiency given that the biogas energy replaces fossil energy, with consideration of costs for plant construction and maintenance; (4) to propose possible methods for utilizing biogas energy generated at centralized biogas plants in cold regions, toward future community development in Hokkaido. II. Form of Utilizing Biogas and Energy Balance Assessment A simulation model was created based on measurement data gathered from centralized biogas plants in operation. The effects of biogas utilization methods on energy balance during plant operation were compared quantitatively for cases in which a gas boiler, a CHP system or a purification system is used, to determine the most efficient biogas utilization method. The greenhouse gas emissions were also measured from the amounts of fossil energy input and methane in the off-gas discharged during refinement, to clarify the environmental burden. The results revealed that the energy production efficiency was the highest for biogas plants treating waste from 1,000 dairy cows using a CHP. The greenhouse gas emission was the smallest in the case using a CHP and the largest in the case using a purification system. The greenhouse gas emission per GJ of output energy in the case of using a purification system was more than ten times that of the case using a CHP. III. Evaluation of energy balance on biogas plant operation from Life Cycle Approach Energy is used in constructing and renovating a biogas plant and in transporting excreta, which is the raw material. However, using the digested slurry that is produced by such plants as fertilizer can reduce the usage of chemical fertilizers. Therefore, it is possible to regard the use of digested slurry for fertilizer as offsetting the energy required to manufacture chemical fertilizer. In light of the above, this section compares the amount of energy that is consumed when a plant is constructed and when excreta is transported to the amount of energy that is produced at a plant (covered in Section II). The aim is to clarify the life-cycle energy balance in consideration of the durable years the facility. It was revealed that the energy output exceeds the energy consumption from the sixth or seventh year of plant operation, regardless of the gas utilization method, i.e., those using a gas boiler, a combined heat and power (CHP) system and a purification system. IV. Form of Utilizing Biogas and Economic Efficiency Assessment Biogas-made energy is supplied from the plant in three forms: heat, electricity and purified gas. These forms of biogas energy can replace several types of fossil energy as alternative. The price and the amount of energy vary according to the fossil energy. In light of this, the economic value of the biogas energy supplied from the plant must be assessed by fossil energy type. Also, the economic efficiency in an energy-generating system needs to be assessed in consideration of expenses for constructing, maintaining and renewing biogas plants. In this section, we compared biogas energy and replaceable fossil energy, and then clarified the life cycle economy of biogas in consideration of the plant's durable years. When we conducted a life cycle assessment of the biogas plant in economic efficiency, its economic balance was found to be negative over 35 years since operation commenced, regardless of converted biogas forms and replaced fossil fuels. We assumed three possible methods for improving the economic balance: reducing expense with construction cost subsidy, increasing revenue by accepting auxiliary feedstock, and increasing unit costs of replaced fossil energy. We then r
Cited by 0 works.