極超音速統合制御実験機排気流による内部ノズルの熱的応答に関する流体・伝熱連成解析
謙 藤井, 亜紀子 松尾, 秀之 田口 et al. · Institutional Repositories DataBase (IRDB) · 2021
In this report, numerical investigation about hypersonic aircraft is conducted to check the applicability of ablator installed in the rear part of hypersonic aircraft.In coupling calculation, surface temperature rise because of heat transfer from exhaust gas to the wall while the amount of heat flux decrease because temperature difference between exhaust gat to the wall decrease.Bottom temperature in the wall does not exceed in 350 K in whole calculation time and then we conclude that he performance of the thermal protection system is sufficient in this structure.In addition, if the surface material is set to cork, temperature gradient in the wall becomes steep because of low thermal conductivity of cork.
Cited by 0 works. Open-access PDF