救急医学および集中治療医学領域における医療機器の有効性に関する臨床研究

伸行 齋藤 · Institutional Repositories DataBase (IRDB) · 2017

REBOA resuscitative endovascular balloon occlusion of the aorta DCR damage control resuscitation PRF pelvic ring fractures ED emergency department ISS injury severity score RTS revised trauma score RBC red blood cells AKI acute kidney injury MOF multiple organ failure RIFLE risk, injury, failure, loss of kidney function, and end-stage kidney disease SOFA sequential organ failure assessment score OR operating room IR interventional radiology AIS abbreviated injury scale TAE trans-arterial embolization PRBC packed red blood cell SS septic shock ICU intensive care unit GNB gram-negative bacilli PMX polymyxin B-immobilized fiber column PMXHP PMX hemoperfusion P/F ratio PaO2 / FiO2 ratio APACHE acute physiology and chronic health evaluation ARDS acute respiratory distress syndrome DIC disseminated intravascular coagulopathy ACS acute coronary syndrome SummaryMedical device (MD) is a large number of types, more than 300, 000 products in Japan, so the evaluation of safety, efficacy, and effectiveness has a high diversity.There is a major difference of recognition in value of a MD among a manufacturing company and clinicians including doctors, nurse, and technician.Clinicians believe that the efficacy of MD is determined by the overall clinical outcome rather than the performance of the product itself.However, it is not required to overall clinical outcome for many of controlled MDs in the new registration.In this thesis, I examined the efficacy of two MDs in the area of emergency and critical care medicine by post-marketing study. Summary of post-marketing study 1Background: Resuscitative endovascular balloon occlusion of the aorta (REBOA) is one of the ultimately invasive procedures for managing a non-compressive torso injury.Since it is less invasive than resuscitative open aortic cross clamping, its clinical application is expected.Methods: We retrospectively evaluated the safety and clinical feasibility of REBOA (intra-aortic occlusion balloon; MERA, Tokyo, Japan) using the Seldinger technique to control severe hemorrhage.Of 5,230 patients admitted to our trauma center in Japan from 2007-2013, we included 24 who underwent REBOA primarily.The indications for REBOA were a pelvic ring fracture (PRF) or hemoperitoneum with hemodynamically instability and impending cardiac arrest.Emergency hemostasis was performed during REBOA in all patients.Results: All 24 patients had a blunt injury, the median age was 59 (interquartile range, 41-71 years), median injury severity score was 47 (37-52), 30-day survival rate was 29.2% (n = 7), and median probability survival rate was 12.5%.Indications for REBOA were hemoperitoneum and PRF in 15 cases and overlap in 8.In 10 cases of death, the balloon could not be deflated in 5.In 19 cases in which the balloon was deflated, the median duration of aortic occlusion was shorter in survivors than in deaths (21 min vs. 35 min, P = 0.05).The mean systolic blood pressure was significantly increased by REBOA (from 53.1 ± 21 mmHg to 98.0 ± 26.6 mmHg, P < 0.01).There were 3 cases with complications (12.5%)-1 external iliac artery injury and 2 lower limb ischemias in which lower limb amputation was necessary in all cases.Acute kidney injury developed in all 3 cases, but failure was not persistent.Conclusions:REBOA appears to be feasible for trauma resuscitation and may improve survivorship.However, the serious complication of lower limb ischemia warrants more research on its safety. Summary of post-marketing study 2The mortality rate associated with septic shock in an intensive care unit (ICU) remains high, with reported rates ranging from 30% to 50%.In particular, Gram-negative bacilli (GNB), which induce significant inflammation and consequent multiple organ failure, are the etiological bacterial agent in 40% of severe sepsis cases.Hemoperfusion using polymyxin B-immobilized fiber (PMX), which adsorbs endotoxin, is expected to reduce the inflammatory sepsis cascade due to GNB.However, the clinical efficacy of this treatment has not yet been demonstrated.Here, we aimed to verify the efficacy of endotoxin adsorption therapy using PMX through a retrospective analysis of 413 patients who received broad spectrum antimicrobial treatment for GNB-related septic shock between January 2009 and December 2012 in 11 ICUs of Japanese tertiary hospitals.After aligning the patients' treatment time phases, we classified patients in two groups regarding whether PMX hemoperfusion (PMXHP) therapy was or was not administered within 24 hours after ICU admission (PMXHP group: n = 134, conventional group: n = 279).The primary study endpoint was the mortality rate at 28 days after ICU admission. Chapter 1 Overall backgroundMedical device (MD) holds a large number of types, more than 300, 000 products in Japan, as compared to the drug in 17,000 products, therefore the evaluation of safety, efficacy, and effectiveness displays has a high diversity.In general, except for a special bioabsorbable material, the shape of MD is universal and its action is either mechanical, and electrical, or physical.Therefore, evaluation of MD, unlike drugs, is carried out by determining the efficacy of the overall clinical outcome rather than the performance of the product itself.However, efficacy of MD is dependent on the user's experience and skill and it must be evaluated by incorporating a variety of factors.There is a major difference of recognition in value of a MD among manufacturing companies and clinicians including doctors, nurses, and technicians.Clinicians believe that the efficacy of MD is determined by the overall clinical outcome rather than the performance of the product itself.However, it is not required to overall clinical outcome for many of controlled MDs in the new registration.In the clinical trials of MDs, some cases were evaluated only for product performance

Cited by 0 works. Open-access PDF

Authors